Microperfusion Pump for Preclinical Use
Application: Microdialysis, Push-Pull Microdialysis, Open Flow Microperfusion, In Vivo and In Vitro Infusions, Preclinical Pharmacology, Pharmacokinetics, Toxicology
You can use the microperfusion pump for large molecule, high-cut off Push-Pull microdialysis work (e.g., peptide microdialysis). Click here for tubing connections. Any high-cut off microdialysis probe can be used in place of the cOFM probe.
Click here to find out how to use the microperfusion pump for general Microdialysis work using Brain Probes
Click here to find out how to use the microperfusion pump for general Microdialysis work using Linear Probes
Item Number | Item Description | Specifications |
OFM-Pump (MPP102PC) |
Microperfusion Pump Preclinical 2 x 3 channels |
- Power supply with main supply or primary battery Adjustable flow rates: 0.1 - 10μl/min flow rate (with an accuracy of ± 20%) |
Item Number | Item Description | Specifications |
OFM-BAG | Perfusate Bag - 10 mL (pack of 6) |
- For use with OFM-Pump |
OFM-P-110 | Single Channel Push Tubing (pack of 6) |
- 110 mm length |
OFM-LT-1000 | Low Bind Tubing 1000 mm Length (pack of 6) |
- For connection from: OFM-P-110 or OFM-P3-110 (push tubing) to probe inlet, probe outlet to OFM-PH or OFM-PH3 (pull side) to collection vial - Can be cut to desired length by the user - Must be used with connectors MD-1510 Click here for tubing specs |
OFM-PP1-LT-1000 | Combined Push-Pull Low Bind Tubing (pack of 6) |
- Used for connection to 1 probe |
OFM-PH3 | Three Channel OFM Pump Head Tubing (pack of 6) |
- 3 channel tubing with PEEK-Port for OFM-Pump Head |
OFM-P3-110 | Three Channel Push Tubing (pack of 6) |
- 110 mm length |
MD-1510 | Flanged Tubing Connectors- clear (pack of 20) |
- Soak connectors in 70% ethanol prior to use. Connectors easily slide on, and then shrink as the alcohol evaporates. (not gamma-irradiated by default, can be gas sterilized upon request when ordering) |
Power supply with main supply or primary battery
- Includes power supply
- Battery not included
Adjustable flow rates: 0.1 - 10μl/min flow rate (with an accuracy of ± 20%)
Resolution:
0.1μl/min at 0.1 – 2.0μl/min flow rate
0.2μl/min at 2.0 – 5.0μl/min flow rate
0.5μl/min at 5.0 – 10.0μl/min flow rate
Typical operating time (with a new battery): up to 48 hours at 1.0μl/min and up to 24 hours at 10μl/min.
Display: LCD with backlight
Dimensions: 130 x 92 x 34.5mm
Total weight: 295g excl. battery and accessories.
Ambient operating temperature: 5 to 40°C
Click for OFM pump user manual.