Epsilon EClipse™

The Epsilon EClipse is the latest electrochemical analyzer manufactured by BASi. It is a potentiostat/galvanostat with a second working electrode for bipotentiostat measurements. Software with the most popular electrochemistry techniques is included with the instrument. 

 

 

The Epsilon EClipseTM is the latest electrochemical analyzer manufactured by BASi. It is a potentiostat/galvanostat with a second working electrode for bipotentiostat measurements. Software with the most popular electrochemistry techniques is included with the instrument.

This System Includes:

  • Basic Software - techniques include
    • Cyclic Voltammetry/Linear Sweep Voltammetry
    • Chronoamperometry/Chronocoulometry
    • Controlled Potential Electrolysis
    • DC Potential Amperometry
    • Open Circuit Potential vs. Time
    • Chronopotentiometry
  • Basic Plus Software - techniques include
    • ‚ÄčSampled Current Polarography
    • Normal Pulse Voltammetry/Polarography
    • Differential Pulse Voltammetry/Polarography
    • Square Wave Voltammetry
    • Stripping Voltammetry Techniques
    • Double Potential Step Chronopotentiometry
  • Methods Software - techniques include
    • Prepare sequences with an unlimited number of techniques
    • Insert trigger and delays in sequence
    • Repeat sequence up to 9999 times
  • Bi-Potentiostat - techniques include
    • Multi-Channel Amperometry
    • Multi-Channel Cyclic Voltammetry 
    • Multi-Channel Chronoamperometry

10’ USB Cable
Bi-Potentiostat cell lead cable

Epsilon EClipse™

Part Number                   

 Description 
EF-1031 Epsilon Eclipse potentiostat/galvanostat  (please specify power   requirements) - requires the use of  a PC
MF-8285 Laptop computer with pre-loaded software

Cell Stands

Part Number

 Description 

EF-1085

 

 

 

 

 

 

 

 

C-3 Voltammetry Cell Stand Package (please specify power requirements)
System includes: 
MW-2980 C3 Cell Accessories Kit
C-3 Cell Stand Accessories Kit includes:
ER-9132 Teflon coated stir bar (1)
MF-1998 Cell lead clips kit (1)
MF-2012 Glassy Carbon Electrode (1)
MF-2013 Platinum voltammetry electrode (1)
MF-2052 RE-5B Ag/AgCl reference electrode (3)
MF-2060 Electrode modifier - PK-4 electrode polishing kit (1)
MF-1208 Glass voltammetry cell vial (12)
Low volume cell vial (2)
MR-5275 Reference electrode storage vial w/cap (1)
MW-1032 Platinum wire aux electrode (1)
MW-1034 Cell top plug (1)

EF-1100

 

 

 

 

 

 

 

 

RDE-2 Rotating Disk Electrode Cell Stand Package (please specify power requirements)
System includes
:
MF-2066 Glassy Carbon Electrode for RDE (1)
RDE-2 Cell Stand Accessories Kit Includes:
MW-1033Coiled Platinum wire auxiliary Electrode for RDE (1)
MF-1208 Glass Cell Vial (12)
MF-2052 RE-5B Reference Electrode (3)
EW-7526 Control Cable 37 pin female to 37 pin male (1)
MF-2060 PK-4 Polishing Kit (1)
MR-4404 Gas Inlet Barb Fitting (1)
MR-5275 Reference Electrode Storage Vial w/Cap (1)
MW-1034 Cell Top Plug (1)
MF-1998 Cell Lead Clips Kit (1)

EF-1400

 

 

 

 

 

 

 

 


 

CGME Controlled Growth Mercury Electrode Cell Stand Package (please specify power requirments) 
System Includes
:
ER-9515 Ribbon cable
CGME Cell Stand Accessories Kit includes:
ER-9132 Teflon coated stir bar (1)
MF-1028 Replacement valve seal
MF-2052 RE-5B Ag/AgCl reference electrode (3)
MF-2069 Mercury collector rod (1)
MF-2090 Beveled glass capillary – 150µm (2)
MF-1208 Glass voltammetry cell vial (12)
Low volume cell vial (2)
MW-1032 Platinum wire aux electrode (1)
MW-1034 Cell top plug (1)
MW-4601 Mercury trap (1)
MF-7150 Vacuum priming pump accessory (1)
MR-5275 Reference electrode storage vial with cap

 Additional Software

Part Number  Description
EF-1646 Basic Plus Software
EF-1663 DigiSim - Simulation Software for ElectroChemistry w/USB key (Not compatible with WIN 10) 

 Replacement cables

 Part Number  Description
ER-9860 Epsilon EClipse bi-potentiostat cable
ER-9861 Epsilon EClipse cell lead cable
ER-9862 Epsilon EClipse cell stand cable
ER-9863  Epsilon EClipse cell lead cable for screen printed electrodes

Other accessories

 Electrodes
 Electrochemical cells

 

Potentiostat

  • Channel 1 applied potential: Dynamic DAC: 16 bit, ±3.275 V @ 0.1 mV resolution or ±10 V @ 0.33 mV resolution
  • Offset DAC: 8 bit, ±2.55 V @ 10 mV resolution
  • Channel 2 applied potential: Dynamic DAC: 8 bit, ±2.55 V @ 10 mV resolution
  • Compliance voltage: ±12 V
  • Maximum current: 100 mA
  • Bandwidth: > 100 kHz
  • Bias current: < 1pA
  • Electrometer input impedance: > 1012W
  • (values for parameters other than applied potential are for both channels)

Current-to-voltage converter

  • Full scale sensitivity: 1 nA*, 10 nA*, 100 nA, 1 µA, 10 µA, 100 µA, 1 mA, 10 mA,100 mA, (*secondary gain used)
  • Secondary gain: x1, x10, and x100
  • ADC resolution: 16 bit
  • Sampling rate: 50 kHz (20 µs/conversion)
  • Data length: up to 64k points - fast

Galvanostat

  • Applied current: 50 pA - 50 mA
  • Range: ±10 V ± 1 V
  • Measured potential resolution: 0.02 mV
  • Max leakage current: 30 pA

I/O

  • Eout (applied potential)
  • Iout (current to voltage output)
  • Ein (input connection for external applied wave form)
  • Cell Stand port (control of C-3 Cell Stand and CGME)
  • Ordering Port (control of RDE-2)
  • PC (USB) port
  • Trigger out (TTL)

Minimum PC requirements

  • Win 7 or higher
  • Pentium III
  • 512 MB RAM
  • 50 MB hard drive space available
  • USB port

Power requirements

  • 120 or 240 VAC, 50/60 Hz, 60 VA

Dimensions & weight

  • 15.75" (40 cm) x 5.25" (13 cm) x 12.75" (32.5 cm)
  • 17.5 lb (7.4 kg) (1 channel)